"accession": "MS:1000201",
"name": "ultraflex",
"definition": "Bruker Daltonics' ultraflex: MALDI TOF.",
"term_type": "instrument"
},
{
"accession": "MS:1000202",
"name": "ultraflex TOF/TOF",
"definition": "Bruker Daltonics' ultraflex TOF/TOF: MALDI TOF.",
"term_type": "instrument"
},
{
"accession": "MS:1000203",
"name": "Voyager-DE PRO",
"definition": "Applied Biosystems/MDS SCIEX Voyager-DE PRO MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000204",
"name": "Voyager-DE STR",
"definition": "Applied Biosystems/MDS SCIEX Voyager-DE STR MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000422",
"name": "beam-type collision-induced dissociation",
"definition": "A collision-induced dissociation process that occurs in a beam-type collision cell.",
"term_type": "dissociation method"
},
{
"accession": "MS:1000447",
"name": "LTQ",
"definition": "Finnigan LTQ MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000448",
"name": "LTQ FT",
"definition": "Finnigan LTQ FT MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000449",
"name": "LTQ Orbitrap",
"definition": "Finnigan LTQ Orbitrap MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000450",
"name": "LXQ",
"definition": "Finnigan LXQ MS.",
"term_type": "instrument"
},
{
"accession": "MS:1000467",
"name": "1200 series LC/MSD SL",
"definition": "The 1200 Series LC/MSD SL ion trap belongs to the Agilent LC/MSD ion trap family. It provides fast polarity switching and multisignal data acquisition capabilities in a single run while also providing 5 stages of automated data dependent MS2 and 11 stages of manual MS2.",
"term_type": "instrument"
},
{
"accession": "MS:1000468",
"name": "6110 Quadrupole LC/MS",
"definition": "The 6110 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with an entry level single quadrupole mass spectrometer from the 6100 Series of Agilent quadrupole mass spectrometers. 6110 Quadrupole mass spectrometer has m/z range of 10-1500 and 2500 u/s scan speed. It proves useful for wide range of SIM quantitative applications.",
"term_type": "instrument"
},
{
"accession": "MS:1000469",
"name": "6120A Quadrupole LC/MS",
"definition": "The 6120A Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 Series of Agilent mass spectrometers. 6120 quadrupole mass spectrometer has m/z range of 10-1500, 2500 u/s scan speed and utilizes multiple signal acquisition.",
"term_type": "instrument"
},
{
"accession": "MS:1000470",
"name": "6130 Quadrupole LC/MS",
"definition": "The 6130 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 series of Agilent mass spectrometers. The 6130 quadrupole mass spectrometer has m/z range of 2-3000, 2500 u/s scan speed in standard mode and 5250 u/s speed in fast-scan mode. It also uses multiple signal acquisition.",
"term_type": "instrument"
},
{
"accession": "MS:1000471",
"name": "6140 Quadrupole LC/MS",
"definition": "The 6140 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 Series of Agilent quadrupole mass spectrometers. 6140 Quadrupole mass spectrometer has m/z range of 10-1350, 2500 u/s scan speed in standard mode and 10000 u/s speed in fast-scan mode. It also uses multiple signal acquisition.",
"term_type": "instrument"
},
{
"accession": "MS:1000472",
"name": "6210 Time-of-Flight LC/MS",
"definition": "The 6210 Time-of-Flight LC/MS is a Agilent liquid chromatography instrument combined with a Agilent time of flight mass spectrometer. This time of flight mass spectrometer has a m/z range of 50-12000, mass accuracy of less than 2 ppm and resolution greater than 13,000 at m/z 2722. It has multiple ion sources and can be used with multimode ion sources.",
"term_type": "instrument"
},
{
"accession": "MS:1000473",
"name": "6310 Ion Trap LC/MS",
"definition": "The 6310 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.35 resolution and mass range of 200-4000 with resolution of 3-4. The scan speed varies from 1650-27000 for the respective mass ranges.",
"term_type": "instrument"
},
{
"accession": "MS:1000474",
"name": "6320 Ion Trap LC/MS",
"definition": "The 6320 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.",
"term_type": "instrument"
},
{
"accession": "MS:1000475",
"name": "6330 Ion Trap LC/MS",
"definition": "The 6330 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.",
"term_type": "instrument"
},
{
"accession": "MS:1000476",
"name": "6340 Ion Trap LC/MS",
"definition": "The 6340 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.",
"term_type": "instrument"
},
{
"accession": "MS:1000477",
"name": "6410 Triple Quadrupole LC/MS",
"definition": "The 6410 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a Agilent triple quadrupole mass spectrometer. Mass range of the mass spectrometer is 15-1650 m/z, resolution is at three settings of 0.7 u (unit), 1.2 u (wide) and 2.5 u (widest). The mass accuracy for 6410 mass spectrometer is 0.1 across the mass range. The collision cell is a hexapole with linear acceleration.",
"term_type": "instrument"
}
]
}