{"count":43797,"next":"https://cinder.proteo.info/api/ms_vocab/?format=json&limit=20&offset=41720&ordering=accession","previous":"https://cinder.proteo.info/api/ms_vocab/?format=json&limit=20&offset=41680&ordering=accession","results":[{"accession":"MS:1000201","name":"ultraflex","definition":"Bruker Daltonics' ultraflex: MALDI TOF.","term_type":"instrument"},{"accession":"MS:1000202","name":"ultraflex TOF/TOF","definition":"Bruker Daltonics' ultraflex TOF/TOF: MALDI TOF.","term_type":"instrument"},{"accession":"MS:1000203","name":"Voyager-DE PRO","definition":"Applied Biosystems/MDS SCIEX Voyager-DE PRO MS.","term_type":"instrument"},{"accession":"MS:1000204","name":"Voyager-DE STR","definition":"Applied Biosystems/MDS SCIEX Voyager-DE STR MS.","term_type":"instrument"},{"accession":"MS:1000422","name":"beam-type collision-induced dissociation","definition":"A collision-induced dissociation process that occurs in a beam-type collision cell.","term_type":"dissociation method"},{"accession":"MS:1000447","name":"LTQ","definition":"Finnigan LTQ MS.","term_type":"instrument"},{"accession":"MS:1000448","name":"LTQ FT","definition":"Finnigan LTQ FT MS.","term_type":"instrument"},{"accession":"MS:1000449","name":"LTQ Orbitrap","definition":"Finnigan LTQ Orbitrap MS.","term_type":"instrument"},{"accession":"MS:1000450","name":"LXQ","definition":"Finnigan LXQ MS.","term_type":"instrument"},{"accession":"MS:1000467","name":"1200 series LC/MSD SL","definition":"The 1200 Series LC/MSD SL ion trap belongs to the Agilent LC/MSD ion trap family. It provides fast polarity switching and multisignal data acquisition capabilities in a single run while also providing 5 stages of automated data dependent MS2 and 11 stages of manual MS2.","term_type":"instrument"},{"accession":"MS:1000468","name":"6110 Quadrupole LC/MS","definition":"The 6110 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with an entry level single quadrupole mass spectrometer from the 6100 Series of Agilent quadrupole mass spectrometers. 6110 Quadrupole mass spectrometer has m/z range of 10-1500 and 2500 u/s scan speed. It proves useful for wide range of SIM quantitative applications.","term_type":"instrument"},{"accession":"MS:1000469","name":"6120A Quadrupole LC/MS","definition":"The 6120A Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 Series of Agilent mass spectrometers. 6120 quadrupole mass spectrometer has m/z range of 10-1500, 2500 u/s scan speed and utilizes multiple signal acquisition.","term_type":"instrument"},{"accession":"MS:1000470","name":"6130 Quadrupole LC/MS","definition":"The 6130 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 series of Agilent mass spectrometers. The 6130 quadrupole mass spectrometer has m/z range of 2-3000, 2500 u/s scan speed in standard mode and 5250 u/s speed in fast-scan mode. It also uses multiple signal acquisition.","term_type":"instrument"},{"accession":"MS:1000471","name":"6140 Quadrupole LC/MS","definition":"The 6140 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a single quadrupole mass spectrometer from the 6100 Series of Agilent quadrupole mass spectrometers. 6140 Quadrupole mass spectrometer has m/z range of 10-1350, 2500 u/s scan speed in standard mode and 10000 u/s speed in fast-scan mode. It also uses multiple signal acquisition.","term_type":"instrument"},{"accession":"MS:1000472","name":"6210 Time-of-Flight LC/MS","definition":"The 6210 Time-of-Flight LC/MS is a Agilent liquid chromatography instrument combined with a Agilent time of flight mass spectrometer. This time of flight mass spectrometer has a m/z range of 50-12000, mass accuracy of less than 2 ppm and resolution greater than 13,000 at m/z 2722. It has multiple ion sources and can be used with multimode ion sources.","term_type":"instrument"},{"accession":"MS:1000473","name":"6310 Ion Trap LC/MS","definition":"The 6310 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.35 resolution and mass range of 200-4000 with resolution of 3-4. The scan speed varies from 1650-27000 for the respective mass ranges.","term_type":"instrument"},{"accession":"MS:1000474","name":"6320 Ion Trap LC/MS","definition":"The 6320 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.","term_type":"instrument"},{"accession":"MS:1000475","name":"6330 Ion Trap LC/MS","definition":"The 6330 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.","term_type":"instrument"},{"accession":"MS:1000476","name":"6340 Ion Trap LC/MS","definition":"The 6340 Ion Trap LC/MS is a Agilent liquid chromatography instrument combined with a 6300 series Agilent ion trap. It has a mass range of 50-2200 between 0.6 to 0.25 resolution and mass range of 200-4000 with resolution of less than 3. The scan speed varies from 1650-27000 for the respective mass ranges.","term_type":"instrument"},{"accession":"MS:1000477","name":"6410 Triple Quadrupole LC/MS","definition":"The 6410 Quadrupole LC/MS system is a Agilent liquid chromatography instrument combined with a Agilent triple quadrupole mass spectrometer. Mass range of the mass spectrometer is 15-1650 m/z, resolution is at three settings of 0.7 u (unit), 1.2 u (wide) and 2.5 u (widest). The mass accuracy for 6410 mass spectrometer is 0.1 across the mass range. The collision cell is a hexapole with linear acceleration.","term_type":"instrument"}]}